A sauna that heats on the first try, a pool pump that does not trip, and a cold plunge on its own circuit. We run the circuits, add the shutoffs and bond the pool, then pull the permit and meet the inspector.
Book online
Enter your ZIP code. If we serve it, you pick the service and a time. It takes about a minute.
Next Phase Electric wires saunas, pools and cold plunges around Covington, Kent and nearby. A traditional sauna heater needs its own 240-volt circuit, sized from the heater's nameplate and manual, often 30 to 60 amps. Infrared saunas and smaller cold plunges often run on a dedicated 120-volt outlet; larger ones need 240 volts. Pools need GFCI-protected circuits for the pump and heater, a shutoff within sight of the equipment, and bonding that ties the metal parts and the water together. We run a load calculation first, because a 100-amp panel often has no room for another big circuit. Most hookups take half a day to a day, and because it is a new circuit, it gets a permit and an inspection.
Saunas inside and out, pools, and the cold plunge next to them.
A 240-volt circuit for the heater, its controls and the light, indoors in a basement or garage, or out to a barrel or cabin sauna.
Most need a dedicated outlet of their own, not one shared with the treadmill. Larger ones take a 240-volt circuit.
GFCI circuits for the pump, heater and lights, a shutoff within sight of the equipment, and outlets kept the right distance from the water.
A dedicated GFCI circuit for the chiller, with the outlet or shutoff placed where the code wants it near water.
Water, heat and big loads. Three things keep them safe.
Sauna heaters and pool heaters are some of the biggest loads in a house. The breaker and wire come from the nameplate, and a load calculation shows the panel can carry it.
Pool and plunge circuits get GFCI protection. A pool also gets bonding: copper tying the pump, the ladder, the metal around the pool and the water together, so there is no voltage difference to feel.
A disconnect near the equipment, so the power can be cut before anyone works on it.
Both heat you up. They need very different power.
| Traditional (heater and stones) | Infrared (heat panels) | |
|---|---|---|
| Power | Its own 240-volt circuit, often 30 to 60 amps. | Often a dedicated 120-volt outlet; larger ones need 240 volts. |
| Heat | Hot air, up to about 190 degrees, with steam off the stones. | Radiant heat, usually 120 to 140 degrees. |
| Panel space | Needs room for a large breaker. A 100-amp panel may be full. | Usually fits on the panel you have. |
| Best for | The classic sauna, indoors or out in the yard. | A spare room or garage, with a lighter electrical job. |
We wire the sauna, pool or plunge you bought, from the maker's installation manual. Send the model or the spec sheet when you book.
Licensed, bonded and insured. Background-checked crew.
Tell us what you are wiring, where it goes, and the model if you have it. A photo of the panel and the spot helps. A technician reaches out within 1 business hour.
The load calculation, the breaker space, and how the circuit gets from the panel to the equipment. Exact price before any work.
Circuit run, shutoff and bonding in, permit pulled and inspected, and the equipment powered up and tested with you.
Three things set the price: the heater size, the distance from the panel, and whether the panel has room. An infrared sauna on a new outlet is the shortest job. You get the exact price before any work starts.
It comes from the heater's nameplate and manual. Home sauna heaters often need a 240-volt circuit of 30 to 60 amps. Many infrared saunas need a dedicated 120-volt outlet of 15 or 20 amps.
A 200-amp panel usually can. A 100-amp panel with electric cooking and a dryer often cannot take another big circuit. We run the load calculation and, if it is short, price a subpanel or a panel upgrade alongside.
Yes. It is a new circuit and it gets inspected. Washington L&I issues the electrical permit in most of our area; Des Moines, Federal Way and Renton issue their own. We pull the permit and meet the inspector.
Copper that ties the pump, the ladder, the metal around the pool and the water together. It keeps everything at the same voltage, so nobody feels a shock stepping between the water and the deck. Every permanent pool needs it.
Yes. The circuit runs underground from the panel or a subpanel to a shutoff at the sauna, then to the heater. A long run across the yard, or a panel on the far side of the house, makes it a full day.
Yes. The chiller should not share a circuit with anything else, and it needs GFCI protection near water. Many run on 120 volts; larger ones need 240. We go by the maker's manual.
An infrared sauna or a cold plunge outlet takes a few hours. A traditional sauna or pool equipment is usually half a day to a day, plus the inspection.
Book online or call. Tell us what you are wiring and where it goes.